引用本文:练迪,黄耀英,朱赵辉,高俊.考虑温度历程的混凝土坝实测应变转换应力分析[J].水利水运工程学报,2017,(6):98-103
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 1053次   下载 782 本文二维码信息
码上扫一扫!
分享到: 微信 更多
考虑温度历程的混凝土坝实测应变转换应力分析
练迪1,2, 黄耀英1, 朱赵辉3, 高俊4
1.三峡大学水利与环境学院,湖北宜昌;2.广东省水文局,广东广州;3.中国水利水电科学研究院,北京;4.上海水务建设工程有限公司,上海
摘要:
由于混凝土各项性能和水泥水化反应密切相关,因此混凝土热学和力学性能的发展不仅与龄期有关,还与自身温度和温度历程有关,而传统混凝土坝实测应变转换应力计算理论中尚未考虑温度历程的影响,这导致转换获得的拉应力并非真实应力。基于等效龄期理论与变形法基本原理,推导了考虑温度历程的实测应变转换应力公式,并给出了考虑温度历程的实测应变转换应力计算步骤;结合西北地区典型混凝土坝对比分析了考虑温度历程及不考虑温度历程的转换应力,分析表明,西北寒冷地区的典型混凝土坝温度范围为6.4~37.0 ℃,考虑温度历程的拉应力与不考虑温度历程的最大差值为0.49 MPa,且差值峰值出现在早龄期,此时混凝土强度尚未充分发展,若不考虑温度历程影响,则无法进行准确的安全评价。
关键词:  混凝土坝  实测应变  温度历程  等效龄期  应力评价
DOI:
分类号:TU528.01; TV42+1.1
基金项目:国家自然科学基金资助项目(51209124)
Analysis of transition from measured strain to stress of concrete dams considering temperature effects
LIAN Di1,2, HUANG Yaoying1, ZHU Zhaohui3, GAO Jun4
1.College of Hydraulic & Environmental Engineering, China Three Gorges University, Yichang;2.Guangdong Province Bureau of Hydrology, Guangzhou;3.China Institute of Water Resources and Hydropower Research, Beijing;4.Shanghai Water Construction Engineering Co., Ltd., Shanghai
Abstract:
Since the performance of concrete is closely related to the cement hydration reaction, the development of the thermal and mechanical properties of concrete is not only related to the age, but also associated with its temperature and temperature history. The influences of the temperature history on the transition from the measured strain to stress are not considered in the traditional theories, which results in an unreal calculated stress. In this paper, the transitional formula from the measured strain to stress in consideration of the temperature process is deduced based on the theory of equivalent age and a deformation method, and the calculation steps are also designed. Based on a typical concrete dam project located in the northwest region, the applicability of the algorithm in this study is verified. Analysis results show that the temperature range is from 6.4 ℃ to 37.0 ℃ in the northwest typical concrete dams, The maximum stress difference is 0.049 MPa whether considering the influences of temperature, so the influences of temperature should not be neglected in this situation. The peak value of the stress differences appears in the early age, and the concrete strength has not yet fully developed at this time. Without considering the influences of the temperature history, an accurate safety assessment can not be carried out for concrete dams.
Key words:  concrete dam  measured strain  temperature process  equivalent age  stress evaluation