引用本文:
【打印本页】   【HTML】   【下载PDF全文】   【查看/发表评论】  【EndNote】   【RefMan】   【BibTex】
过刊浏览    高级检索
本文已被:浏览 27次   下载 0次  
基于熵产理论的X型双向泵站流道优化设计研究
顾明阳1, 王少波2, 陆 雯2, 江涛2, 徐 磊1, 陆伟刚1
1.扬州大学;2.江苏省水利勘测设计研究院有限公司
摘要:
X型双向流道泵站因其进出水流道需通过急弯、扩散和收缩等过渡段,水流极易出现大范围脱流和旋涡,导致显著的水头损失,为改善水力性能,本文以某X型双向泵站为对象,将CFX数值模拟与熵产理论相结合,对进出水流道喇叭管结构进行逐步优化,以最小化水力损失为目标。数值模拟采用雷诺时均方程和RNG k-ε湍流模型计算内流场,并基于熵产理论,通过参数化调整进、出水流道喇叭管直径(以叶轮直径D为基准),以总熵产为评价指标进行寻优。结果表明:进水流道流速相对较低、壁面面积大,总熵产主要由壁面熵产贡献;而出水流道存在剧烈速度梯度和流动分离,湍流熵产占绝对主导。本文计算较优方案为进水流道喇叭管直径取1.625D、出水流道喇叭管直径取2D,此时全流道总熵产达到最小值,水力损失最低。针对优化后的进出水流道进行泵装置模型实验,泵装置模型实验与数值模拟结果趋势一致且误差在5%以内,符合工程实际要求本文提出的优化方法与结论可为同类X型双向流道泵站喇叭管设计提供参考。
关键词:  双向流道  熵产理论  水力性能优化  数值模拟  物理模型实验
DOI:
分类号:TV675
基金项目:
Study on flow passage optimization design of an X-shaped bidirectional pumping station based on entropy production theory
GU Mingyang1, WANG Shaobo2, LU Wen2, JIANG Tao2, XU Lei1, LU Weigang1
1.Yangzhou University;2.Jiangsu Water Conservancy Survey and Design Institute Co,Ltd
Abstract:
X-type bidirectional passage pumping stations require the inlet and outlet passages to go through transition sections such as sharp bends, expansions, and contractions, where the flow is highly prone to large-scale separation and vortices, resulting in significant head losses. To improve the hydraulic performance, this study takes an actual X-type bidirectional pumping station as the research object and combines CFX numerical simulation with entropy production theory to perform stepwise optimization of the bell mouth structures of the inlet and outlet passages, with the objective of minimizing hydraulic losses. The numerical simulation adopts the Reynolds-averaged Navier–Stokes equations and the RNG k-ε turbulence model to compute the internal flow field. Based on entropy production theory, the bell mouth diameters of the inlet and outlet passages (with the impeller diameter D as the reference) are parametrically adjusted, and the total entropy production is used as the evaluation index for optimization. The results show that in the inlet passage, where the flow velocity is relatively low and the wall surface area is large, the total entropy production is mainly contributed by wall entropy production; whereas in the outlet passage, due to severe velocity gradients and flow separation, turbulent entropy production plays an absolutely dominant role. The optimal scheme identified in this paper is an inlet bell mouth diameter of 1.625D and an outlet bell mouth diameter of 2D, at which the total entropy production of the entire passage reaches its minimum and the hydraulic loss is the lowest. A pump device model experiment was conducted for the optimized inlet and outlet passages. The model test results exhibit trends consistent with the numerical simulation results, and the error is within 5%, meeting the requirements of engineering practice. The optimization method and conclusions proposed in this paper can provide a reference for the bell mouth design of similar X-type bidirectional passage pumping stations.
Key words:  Bidirectional Flow Channel  Entropy Production Theory  Hydraulic Performance Optimization  Numerical Simulation  Physical Model Test.