引用本文:张绪进,吕伟东,刘平昌,彭永勤.贵港航运枢纽二线船闸输水系统水力学试验[J].水利水运工程学报,2012,(4):34-38
【打印本页】   【HTML】   【下载PDF全文】   查看/发表评论  【EndNote】   【RefMan】   【BibTex】
←前一篇|后一篇→ 过刊浏览    高级检索
本文已被:浏览 850次   下载 753 本文二维码信息
码上扫一扫!
分享到: 微信 更多
贵港航运枢纽二线船闸输水系统水力学试验
张绪进,吕伟东,刘平昌,彭永勤
重庆交通大学西南水运工程科学研究所;广西西江开发投资集团有限公司
摘要:
贵港航运枢纽位于贵港市上游6.5 km处西江郁江河段,船闸设计有效尺度280 m×34 m×5.6 m(长×宽×门槛水深),采用闸墙长廊道多支管分散输水系统形式,设计最大水头14.1 m.通过对输水系统水力特性、廊道压力、闸室和上下游进出口流态、船舶(队)系缆力的观测,提出了上闸首阀门后廊道高程、闸室三明沟消能等部位的合理布置方案,杜绝了充水过程中的门后检修门井掺气,进一步均匀闸室内横向水流分配,使得设计船(队)舶的泊稳条件更好地满足规范要求.研究表明采用闸墙长廊道多支管输水型式是可行的.
关键词:  船闸  输水系统  试验研究
DOI:
分类号:U641.32
基金项目:
Hydraulic experiment for the second-line ship-lock’s filling-emptying system of Guigang navigation project
ZHANG Xu-jin,LV Wei-dong,LIU Ping-chang,PENG Yong-qin
1(1.Chongqing Southwest Water Transport Engineering Research Institute,Chongqing 400016,China;2.Guangxi Xijiang Development and Investment Group Co.,Ltd.,Nanning 530022,China)
Abstract:
Guigang navigation project is located in the Yujiang River reach of the Xijiang River,which is 6.5 km away upstream of Guigang city.The effective scale of ship lock design is 280 m×34 m×5.6m(length×width×doorsill water depth),and the filling-emptying system adopts the long gallery manifold dispersion form.The design water head is 14.1m.Through observation of the hydraulic characteristics of the filling-emptying system,gallery pressure,flow state at the exit and entrance of upstream and downstream,gate chamber,and ships’ mooring force,we have proposed a reasonable arrangement scheme of upper lock head gallery elevation behind valve,and three open ditches energy dissipation in the gate chamber.And we put an end to the overhaul shaft aeration in the process of water filling,make the distribution of transverse water flow uniform further,and make the berth stability of the designed fleet satisfy the standards.The research results show that the lock’s long gallery manifold dispersion filling-emptying form is feasible.
Key words:  ship lock  filling-emptying system  experimental research
手机扫一扫看